The ML42 measures level and liquid-liquid interface by buoyancy: a displacer suspended from a torque tube converts level change into a precise digital signal. Multi-point linearization, self-compensation and continuous self-diagnostics deliver ±0.5% FS accuracy with high long-term stability, and SIL2/3 certification covers safety-related service.
The full-text graphic LCD shows current, process variable, temperature and percent of range, and the meter adapts to the measuring point on site without calibration. Built-in RFI/EMI filtering keeps the signal clean in electrically noisy plants.
Key Features
- Level and interface measurement with medium density difference from 0.08 g/cm3
- Process temperature -70 C to +450 C, pressure up to PN420 (Class 2500)
- Torque tube in Inconel 600 standard; Monel and Hastelloy-276 options; wetted parts 304 / 316L
- Smooth filtering algorithm for a stable output signal
- HART communication, 4-20mA output; Modbus and wireless LoRa options
- IP66; explosion-proof versions Ex ia / Ex d