Email: admin@hainameter.com WhatsApp: +86 15671082677
MF16 Micro Flow Metal Tube Rotameter (Low Flow Meter)

MF16 Micro Flow Metal Tube Rotameter (Low Flow Meter)

Micro-flow metal tube rotameter for tiny liquid and gas flows — water 1 to 100 L/h, air 30 to 3,400 NL/h — with needle valve, pointer, transmitter or switch versions.

Key Specifications

Model
MF16
Principle
Variable area (float), magnetic coupling
Size / Connection
1/4"–1/2" NPT, 6–12 mm ferrule, DN15 flange
Measuring range
Water 1–100 L/h; Air 30–3,400 NL/h
Accuracy
Pointer class 4.0 / 2.5; transmitter & switch versions class 1.5
Output / Protocol
Local pointer; two-wire 4–20mA + HART7; up to two NAMUR limit switches

Category: Flow Meters » Metal Tube Rotameter

Keywords:micro flow rotameterlow flow metermetal tube rotameter for gasneedle valve rotametersmall flow measurement

The MF16 is the micro-flow version of the MF1 metal tube rotameter, made for analyzer systems, purge panels and precision dosing. Actual-flow scales with a 10:1 turndown, an integral needle valve for setting the exact flow, inlet filtration and an outlet check valve protect the float from sticking and clogging.

Three versions cover indication, transmission and alarming: mechanical pointer, LCD two-wire transmitter (4-20mA + HART7) and limit-switch versions with up to two NAMUR switches at class 1.5 accuracy. Wetted parts are 316L and ratings reach PN400 / Class 2500 at -80 C to +200 C.

Key Features

Technical Specifications

Measuring rangeWater 1-100 L/h; Air 30-3,400 NL/h
Turndown ratio10:1
AccuracyPointer version class 4.0 / 2.5; transmitter and switch versions class 1.5
OutputLocal pointer; two-wire 4-20mA + HART7; up to two NAMUR limit switches
Process temperature-80 to +200 C
Pressure ratingUp to PN400 / Class 2500
Process connection1/4, 3/8, 1/2 NPT; 6/8/10/12 mm ferrule; DN15 flange
Wetted material316L stainless steel
Protection classIP65
Explosion protectionEx ia IIC T6 Ga (optional, transmitter / switch versions)

FAQ

What is the smallest flow the MF16 can measure?

From 1 L/h of water or 30 NL/h of air, with a 10:1 turndown and actual-flow (not converted) scales.

Can the MF16 output a signal or alarm?

Yes. The transmitter version gives two-wire 4-20mA with HART7, and the switch version provides up to two NAMUR limit switches for alarm and control at class 1.5 accuracy.

Where is the MF16 typically used?

Analyzer and sampling systems, gas purge panels, chemical dosing of additives and catalysts, specialty gas monitoring and precise small-flow control in fine chemical and biopharma processes.

Request a Quote

Send your medium, pipe size, flow range, temperature and pressure to admin@hainameter.com or WhatsApp +86 15671082677.