Email: admin@hainameter.com WhatsApp: +86 15671082677
MF1 Metal Tube Rotameter (Variable Area Flow Meter)

MF1 Metal Tube Rotameter (Variable Area Flow Meter)

All-metal variable area flow meter for liquids, gases and steam, from -196 C to +450 C and up to 42 MPa, with modular transmitter and 14 self-diagnostics.

Key Specifications

Model
MF1
Principle
Variable area (float), magnetic coupling
Size / Connection
DN15–DN200 (1/2"–8")
Measuring range
Water 1.0–200,000 L/h; Air 0.05–6,000 m3/h
Accuracy
Class 1.5 standard; Class 1.0 special version
Output / Protocol
4–20mA / HART7, FF, PROFIBUS-PA, Modbus, Ethernet-APL; local pointer

Category: Flow Meters » Metal Tube Rotameter

Keywords:metal tube rotametervariable area flow meter4-20mA rotameterrotameter for steamhigh pressure flow meter

The MF1 is an all-metal variable area (float) flow meter for liquids, gases and steam. A magnetically coupled float drives the local pointer and the modular transmitter without any additional penetration of the measuring tube, so the meter stays leak-tight at pressures up to 42 MPa (Class 2500) and process temperatures from -196 C to +450 C.

Vertical bottom-in/top-out, top-in/bottom-out and horizontal installations are available, together with high-temperature, cryogenic, jacketed, hygienic and PTFE/PFA-lined corrosion-resistant versions. The modular transmitter can be exchanged or upgraded on site, and 14 built-in self-diagnostics watch the sensor, float and electronics continuously.

Key Features

Technical Specifications

Nominal diameterDN15–DN200 (1/2"–8")
Process connectionstandardflange HG/T 20592-2009, HG/T 20615-2009; optional GB/T 193-2003 thread, GB/T 12716-2011 NPT thread, QB/T 2004-1994 standard
Measuring range(20°C)1.0 ~ 200000 L/h: (0°C, 0.1013 MPa)0.05~6000 m³/h
Accuracy / repeatabilitystandard 1.5 ; special 1.0, 2.0, 2.5, 4.0 ; better than ±0.3%
Turndown ratiostandard 10 : 1; special 20 : 1, max. 100:1
Pressure loss2 kPa ~ 50 kPa
Process temperaturestandard -40–+120°C (with heat tracing -80–+200°C); -40–+450°C; -196–+80°C; PTFE -40–+100°C; PFA -40–+120°C
Process pressurePN16, PN25, PN40, PN63, PN100, PN160, PN250, PN320, PN400; Class150, 300, 600, 900, 1500, 2500
Viscosity rangeDN15(K1.0~1.3): 5 mPas; DN15 (K1.4~1.10): 30 mPa.s; DN25(K2.0~2.2): 80 mPa.s; DN25 (K2.3~2.7): 150 mPa.s; DN50~DN100: 240mPa.s; DN150~DN200: 300mPa.s
Housing materialcast aluminum, polyester coated; 304 316 stainless steel; 304 316 stainless steel
Ambient temperaturelocal indication -40–+120°C; remote transmission -40–+85°C (LCD -20–+70°C); intrinsically safe, flameproofbattery version -40–+60°C
Two-wire output24VDC , 4–20mADC , white backlight LCD; 4–20mADC+HART7, white backlight LCD
Four-wire output12VDC 24VDC , RS485/Modbus, white backlight LCD
Switch outputopen collector: , 30VDC/100mA; dry contact: , 175VDC/0.5A; NAMUR: two-wire
Damping / data storage0–32s; data retention ≥10
Communication protocolHART7 ( BEJING MASTER 0x619A, MF1 EsH/EsN 0xE638, FSK); FOUNDATION Fieldbus H1/ITK6.4 ( 0x000168, MF1 EsFF 0x0001); PROFIBUS-PA 3.02 (MF1 EsPA); Modbus-RTU; Ethernet-APL 10Mbps (EsAP), optional HART-IP PROFINET
Explosion protectionPCEC: Ex ia IIC T1–T6 Ga, Ex iaD 20 T80°C–T440°C, Ex d IIC T1–T6 Gb, Ex tD A21 T80°C–T400°C; battery version Ex ia IIC T4 Ga; ATEX, EAC
Safety / metrology certificationSIL3 (IEC 61508 Parts 1-7:2010); CPA, PAC, KIM
EMC / PED / TSG2014/30/EU, EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019; PED 2014/68/EU Module H
Protection classIP66/IP67, GB 4208/IEC 60529
Surge protectionoptional , 2KV, 4KV(4 )
Electrical connection1/2NPT, M20×1.5 or other sizes
Ambient humidity / storage temperature5%–95%; -45–+85°C

Flow Range by Size

DNFlow rangeUnit
DN15 - DN2001.6 - 200,000 (water, 20°C)L/h

Materials & Options

Measuring tube and float in 304, 316, 304L, 316L, 304/PTFE, 316/PTFE, PTFE, Hastelloy, titanium, Inconel, Monel or ceramic. Indicator housing in cast aluminium or 304/316 stainless steel. Jacketed version available for crystallising media.

Downloads

FAQ

What media can the MF1 measure?

Liquids, gases and steam. Wetted parts are available in stainless steel, PTFE/PFA lining, Hastelloy, titanium and other alloys, so corrosive media such as sulfuric acid, hydrochloric acid and caustic soda can be metered.

What is the measuring range of the MF1?

DN15 to DN200. Water range 1.0 to 200,000 L/h and air range 0.05 to 6,000 m3/h, with a standard turndown of 10:1 (20:1 special, up to 100:1).

Which output signals does the MF1 provide?

Two-wire 4-20mA with HART7, four-wire RS485/Modbus, FOUNDATION Fieldbus, PROFIBUS-PA and Ethernet-APL versions, plus local pointer indication and optional alarm switches.

Request a Quote

Send your medium, pipe size, flow range, temperature and pressure to admin@hainameter.com or WhatsApp +86 15671082677.