Email: admin@hainameter.com WhatsApp: +86 15671082677
MLC Bubbler Level Transmitter (Purge-Type Level Gauge)

MLC Bubbler Level Transmitter (Purge-Type Level Gauge)

Bubbler-type level transmitter that measures level, density and interface without contacting the medium — for high-temperature, high-viscosity, crystallizing and radioactive services.

Key Specifications

Model
MLC
Principle
Bubbler (air purge) hydrostatic
Size / Connection
Flanges DN50–DN150
Measuring range
Measuring range 0–50 m
Accuracy
±0.1% FS (incl. linearity and repeatability)
Output / Protocol
4–20mA DC two-wire with HART

Category: Level Transmitters » Bubbler Level System

Keywords:bubbler level transmitterair purge level measurementlevel transmitter for viscous medianon-contact level measurement

The MLC measures level hydrostatically through a purge (bubbler) tube: apart from the dip tube, nothing contacts the medium, so it keeps working where contact instruments fail — high temperature (media -196 C to +450 C), high vacuum, viscous, crystallizing, radioactive and heavily fouling liquids.

Built with the MFC1 purge device as a complete bubbler system, it offers linear correction, automatic error compensation and self-diagnostics, with a dot-matrix LCD and local keys for setup. Anti-clogging, anti-backflow and heat-traced designs are available.

Key Features

Technical Specifications

Nominal pressureANSI: 150lb, 300lb, 600lb GB: 1.6MPa, 4.0MPa, 6.3MPa, 10MPa
Medium temperature-196~450°C
Installationtop or side mounting
Connection sizesDN50 ~ DN150 flange (contact us for details)
Ambient temperatureintrinsically safe: -30~60°C; flameproof: -20~60°C
Ambient humidity10%~90%RH
Air supply pressure0.4MPa
Purge air flowmax. 400L/h (20°C, standard)
Wetted materials304, 304L, 316, 316L, 321 etc.stainless steel
Local displaydot-matrix LCD, dot-matrix LCD display
Output4~20mA DC, two-wire
Standard version12V–40VDC
Intrinsically safe version12V–30VDC
Flameproof version12V–40VDC
Load resistance≤( Us – 12V) / 22.5mA (Us = supply voltage)
CommunicationHART , 250Ω
Accuracy±0.1%FS (incl. linearity and repeatability)
Protection classIP65
Cable entryM20×1.5(F), 1/2″NPT(F)optional
Data setting(4~20mA 20~4mA) (mm, m), and

FAQ

How does a bubbler level transmitter work?

A constant flow of purge air is fed down a dip tube; the back-pressure in the tube equals the hydrostatic pressure of the liquid column, which the transmitter converts into level, density or interface.

Where is the MLC the best choice?

In dirty, viscous, crystallizing, high-temperature or radioactive services — crude and sludge tanks, sewage and slurry pits, HF and sulfuric acid tanks — where contact instruments clog or corrode.

What does the MLC need to operate?

A clean air supply above 0.4 MPa and the MFC1 purge device to hold the purge flow constant (max. 400 L/h per line).

Request a Quote

Send your medium, pipe size, flow range, temperature and pressure to admin@hainameter.com or WhatsApp +86 15671082677.