The MF16 is the micro-flow version of the MF1 metal tube rotameter, made for analyzer systems, purge panels and precision dosing. Actual-flow scales with a 10:1 turndown, an integral needle valve for setting the exact flow, inlet filtration and an outlet check valve protect the float from sticking and clogging.
Three versions cover indication, transmission and alarming: mechanical pointer, LCD two-wire transmitter (4-20mA + HART7) and limit-switch versions with up to two NAMUR switches at class 1.5 accuracy. Wetted parts are 316L and ratings reach PN400 / Class 2500 at -80 C to +200 C.
Key Features
- True micro-flow ranges: water 1–100 L/h, air 30–3,400 NL/h
- Integral needle (trim) valve; inlet filter and outlet check valve fitted
- Side-in/side-out and bottom-in/top-out connections; NPT, ferrule and DN15 flange
- Pointer, LCD transmitter or limit-switch versions; LCD shows instantaneous and total flow
- 316L wetted parts, IP65; Ex ia IIC T6 Ga option