MFC1 Purge Rotameter (Constant Flow Purge Device)

MFC1 Purge Rotameter (Constant Flow Purge Device)

Constant-flow purge device combining a micro metal tube rotameter with a differential control valve — holds purge flow steady when system pressure or load changes.

Key Specifications

Model
MFC1
Principle
Metal tube float meter + constant differential pressure control valve
Size / Connection
DN10–DN50 (MFC16 micro / MFC10 versions)
Measuring range
Water 3–25,000 L/h; Air 50–7,000 NL/h (0.7–800 Nm3/h)
Accuracy
Constant flow held automatically against pressure / load changes
Output / Protocol
Local indication with regulating valve (purge flow set point)

Category: Purge Devices

Keywords:purge rotameterconstant flow purge devicepurge flow controllerdifferential pressure purge meter

The MFC1 combines a micro metal tube float flow meter with a constant-flow control valve. When system pressure or load changes, the valve automatically holds the set purge flow constant — the basis of reliable bubbler level measurement and instrument purging.

Two control arrangements cover both cases: the RE type with the valve upstream suits constant outlet pressure or vented service, while the RA type downstream suits constant inlet pressure. Local indication plus a regulating valve make commissioning and routine adjustment simple.

Key Features

Technical Specifications

VersionsMFC16 (micro flow) and MFC10 (standard)
SizesDN10-DN50
Controlled flow - water3-25,000 L/h
Controlled flow - air50-7,000 NL/h (0.7-800 Nm3/h)
Pressure ratingUp to PN400 / Class 2500
Process temperatureStandard -80 to +150 C; high-temperature version -196 to +300 C
Control typesRE type (valve upstream) and RA type (valve downstream)

FAQ

What is the MFC1 used for?

It supplies a constant purge flow to bubbler level systems and to transmitter tapping points in refining, chemical, ethylene, fertilizer, steel and fiber plants, preventing clogging and back-diffusion of corrosive gases.

RE or RA type — which one?

Choose RE (valve upstream) when outlet pressure is constant or the line vents to atmosphere; choose RA (valve downstream) when inlet pressure is constant. For liquid service both behave the same.

What flows can it control?

Water from 3 to 25,000 L/h and air from 50 NL/h to 800 Nm3/h across the MFC16 and MFC10 (DN10–DN50) versions.

Request a Quote

Send your medium, pipe size, flow range, temperature and pressure to admin@hainameter.com or WhatsApp +86 15671082677.